RoomScene 3D
Download

Zabbix in 3D

3D visualization of your equipment rooms for Zabbix

Zabbix knows that a power supply failed. It does not know that the server sits in rack B07 at U16, behind the CRAC unit. RoomScene 3D puts the Zabbix problem where the hardware is.

Download the 30-day trial Ask for a quote

Top view of a rack room with an inlet temperature heat map
Fig. 1 Top view with the inlet temperature heat map (18–28 °C). The same overlay can show U usage, power or weight.

What Zabbix maps leave out

Zabbix network maps are good at topology: which switch feeds which host. They are drawn by hand, in 2D, and have no idea of a room, a rack or a U position. When a trigger fires at night, the on-call engineer still has to find the box.

How RoomScene 3D reads Zabbix

  • One connection, a read-only API token. Nothing is written to Zabbix.
  • Each inventory device is linked to a Zabbix host. When you start, hosts with matching names are linked automatically; the rest wait in an unplaced list filtered by host group.
  • Open problems are drawn on the device in Zabbix severity colours. The rack takes the worst colour of its devices and glows; the room list shows a count.
  • Severity counters in the toolbar filter the scene: show only Disaster and High, for example.
  • Problems of disabled hosts and triggers are left out.
  • The device card links to the host in Zabbix for graphs and history. RoomScene 3D does not copy history.

Where each Zabbix value appears

From ZabbixIn RoomScene 3D
Open problems and trigger severityDevice colour, rack glow, room counter, device card
Host groupsInventory filter, unplaced list, device type guess
PDU power items (W, kW), total or per phaseMeasured rack power, power heat map, A/B feed load
Inlet and ambient temperature (°C)Temperature heat map, rack card
Hosts without an inventory recordReconciliation list

Power and temperature items are read every two minutes. For PDUs the total item is used, or the sum of the phases if there is no total; outlet, rated and peak items are ignored. For temperature only inlet and ambient sensors count. A rack without a PDU takes the sum of its devices' own power readings.

Equipment rooms, not only data halls

RoomScene 3D was built in a broadcast facility. Besides rack rooms it models studios, galleries and control rooms with cameras, monitor walls, LED walls and lighting. A camera CCU or an LED processor monitored in Zabbix shows its problem on the camera or the wall in the studio, not just in a list.

Rooms or devices without Zabbix

Not everything is in Zabbix. Switch on the built-in check and devices with a management IP are pinged or checked on a TCP port. Three missed rounds open a High problem in RoomScene 3D; it clears when the device answers. Devices linked to Zabbix are left to Zabbix.

Questions

Does it need Zabbix maps or a special template?

No. It uses hosts, problems and items you already have. For power and temperature, standard PDU and sensor items are recognised by their units and key patterns.

What if Zabbix is down?

The rooms and the inventory stay available. Status shows when the last successful read happened, so nobody mistakes stale data for healthy.

Try it on your own rooms

Install the trial on a test server, import one room from Excel and connect monitoring. Questions, quotes and licence requests: contact@roomscene3d.com.

Download the 30-day trial Ask for a quote

contact@roomscene3d.com · tahirfeyzioglu@gmail.com